Index>News>Introduction to Testing and Installation of PTFE lined Valves

TIME:2015-12-04 Source: This site

Introduction to Testing and Installation of PTFE lined Valves

Nowadays, valves play an increasingly important role in various industries. The regulation and cutting off of the medium have continuously expanded its market size. Each type of valve has significant differences in its driving method, applicable environment, control accuracy, and installation method. Based on different performance, choose appropriate valve products according to the actual situation to ensure the normal operation of the system.
We can mention this PTFE lined valve Testing and installation operations. As is well known, valves such as PTFE lined butterfly valves have greatly enhanced corrosion resistance due to their special materials, far superior to other types of valve products, and their testing and installation also have their own particularities. Before installation, confirm whether the performance of our product and the flow direction arrow of the medium are consistent with the operating conditions, and clean the inner cavity of the PTFE lined valve. It is not allowed to have impurities or foreign objects on the sealing ring and butterfly plate. The butterfly plate must not be closed before cleaning to avoid damaging the sealing ring. It is recommended to use a special flange for PTFE lined disc valves for the installation of disc plates. It should be installed in a vertical position in the pipeline, but not inverted. During use, it is necessary to adjust the flow rate, which is controlled by a worm gear box. For PTFE lined butterfly valves with a high frequency of opening and closing, after about two months, open the worm gear box cover and check if the butter is normal, and maintain an appropriate amount of butter. Check that all connecting parts are tightly pressed to ensure the honeycomb properties of the packing and the flexible rotation of the valve stem. PTFE lined butterfly valves are not suitable for installation at the end of pipelines. If they must be installed at the end of pipelines, it is necessary to install outlet flanges to prevent the accumulation of sealing rings. The installation and use of valve stems should be checked regularly to ensure the effectiveness of PTFE lined valves. Any faults found should be promptly resolved.

Key points to note when using PTFE lined valves

衬氟对夹蝶阀D371F46-16C

Fluorine lined butterfly valve D371F46-16C

Prev 2012-05-08

The compression molding process in the clamp type fluorine lined butterfly valve

Next 2015-12-05

How to avoid a decrease in the service life of fluorine lined check valves

Hotline 0577-86860737

Copyright © 2026 Zhejiang Lierduo Valve Co., Ltd. All Rights Reserved.

浙ICP备10012193号-3