    PTFE lined valve It is a type of fluorine lined valve that is widely used in various fields such as petroleum, printing and dyeing, and chemical engineering due to its strong corrosion resistance.
As mentioned earlier, PTFE lined valves are specifically designed to control corrosive or highly corrosive media, so their stability is important. Problems can cause significant economic losses and serious consequences, so timely handling of their faults is particularly important. Below, Lieldo PTFE lined valve factory will introduce several troubleshooting methods for PTFE lined valves.
1、 Valve body leakage:
Reason:
1. The valve body has sand holes or cracks,
2. The valve body cracked during welding repair,
Repair method:
1. Polish the suspected crack area and etch it with a 4% nitric acid solution. If there are cracks, they will be visible,
2. Excavate and repair the crack area.
衬氟电动放料球阀
2、 Damage to the valve stem and its mating threads, or breakage of the valve stem head or bending of the valve stem:
Reason:
1. Improper operation, excessive force on the switch, malfunction of the limit device, and failure to activate the over torque protection.
2. The thread fit is too loose or too tight.
3. Too many operations and too long service life.
Repair method:
1. Improve operation, do not apply excessive force; Check the limit device and the torque protection device.
2. Choose appropriate materials and ensure assembly tolerances meet the requirements.
3. Replace spare parts.
衬四氟阀门厂家
3、 Valve cover joint surface leakage:
Reason:
1. Insufficient or biased tightening of bolts.
2. The gasket does not meet the requirements or the gasket is damaged.
3. The joint surface has defects.
Repair method:
1. Tighten the bolts or make the gap between the door cover flange consistent.
2. Replace the gasket.
3. Disassemble and repair the sealing surface of the door cover.