Index>News>How to solve the problems of internal and external leakage of fluorine lined gate valves?
TIME:2023-12-01 Source: This site
In the industrial field, Fluorine lined gate valve The problem of internal and external leakage can be said to be quite common, so how can we solve such a problem? Today, the editor will provide a detailed introduction for everyone.
1. External leakage handling method:
Sino French flange leakage: In the case of Sino French flange leakage, the first step is to try tightening the bolts of the middle flange again. If the problem is still not resolved, it is necessary to check whether the flange gasket is damaged. If it is damaged, it needs to be replaced.
Leakage at the packing point: To address the issue of water leakage at the packing point, it is necessary to tighten the packing gland. If the packing is loose, it should be added in a timely manner. If the leakage is directly caused by the valve body, welding repair can be attempted for low-pressure systems; As for the high-pressure system, in order to ensure safety, repair should be abandoned and new valves should be replaced.